SPHERICAL TANK STRENGTH CALCULATION
POV : Period Of Vibration (°íÀ¯Áøµ¿Áֱ⠰è»ê)   ALLOWABLE STRESS Spherical tank ¿ë·® ¹× Column Ç¥ÁØÈ­ [PDF]
kid°ßÀû¹øÈ£ÇÁ·ÎÁ§Æ®¸í¼³¸íCustomerSite Locationµî·ÏÀÚ¸í[Á¶È¸][¼öÁ¤][SVG Calc]
9SK_EC2SK_ECSK_ECSK_EC¼Û±æ¼ö[Á¶È¸][¼öÁ¤]SVG Calc
8´ë¸¸ CPC4Á¾´ë¸¸ CPC´ë¸¸ CPC´ë¸¸ CPC¼Û±æ¼ö[Á¶È¸][¼öÁ¤]SVG Calc
7´ë¸¸ CPC4Á¾´ë¸¸ CPC´ë¸¸ CPC´ë¸¸ CPC¼Û±æ¼ö[Á¶È¸][¼öÁ¤]SVG Calc
6JAPAN 32mTHE SEISMIC DESIGN MARGINS FOR SPHERICAL GAS TANKSJAPAN 32mJAPAN 32mJAPAN 32m¼Û±æ¼ö[Á¶È¸][¼öÁ¤]SVG Calc
5LSP-PROP-TESTVIETANM LSP SPHERICAL TANK (4Á¾10±â)¼öÁÖÈÄ µ¥ÀÌŸ ÀÔ·ÂPVS-MSVIETANM LON-SON¼Û±æ¼ö[Á¶È¸][¼öÁ¤]SVG Calc
4LSP-PROP-001VIETANM LSP SPHERICAL TANK (4Á¾10±â) Å×½ºÆ®¼öÁÖÈÄ µ¥ÀÌŸ ÀÔ·ÂPVS-MSVIETANM LON-SON¼Û±æ¼ö[Á¶È¸][¼öÁ¤]SVG Calc
3LSP-PROP-001VIETANM LSP SPHERICAL TANK (4Á¾10±â)¼öÁÖÈÄ µ¥ÀÌŸ ÀÔ·ÂPVS-MSVIETANM LON-SON¼Û±æ¼ö[Á¶È¸][¼öÁ¤]SVG Calc
2LSP-PROP-001VIETANM LSP SPHERICAL TANK (4Á¾10±â)¼öÁÖÈÄ µ¥ÀÌŸ ÀÔ·ÂPVS-MSVIETANM LON-SON¼Û±æ¼ö[Á¶È¸][¼öÁ¤]SVG Calc
1LSP-PROP-001VIETANM LSP SPHERICAL TANK (4Á¾10±â)¼öÁÖÈÄ µ¥ÀÌŸ ÀÔ·ÂPVS-MSVIETANM LON-SON¼Û±æ¼ö[Á¶È¸][¼öÁ¤]SVG Calc

¡á Design Data : THE SEISMIC DESIGN MARGINS FOR SPHERICAL GAS TANKS
¹øÈ£TANK NO.TNO =V-1110A/BV-1110A/BV-1110A/BREMARK
2DESIGN CODE ( ASME SEC. VIII ) CODE =DIV. 1DIV. 1DIV. 2
3STORAGE LIQUID NAMECONTENT =1,3 Butane1,3 ButanePropylene
4DESIGN SPECIFIC GRAVITYSG =0.62150.62150.59
5MATERIAL OF SHELL PLATEMATL =SA516-70SA516-70SA537-CL2
6DESIGN TEMPERATURE (Max.)¡ÉDTEMP =686868
7ALLOWABLE STRESS at Deisin(Operaing)MPaSd =138.00138.00230.00ALLOWABLE STRESS
8TANK INSIDE DIAMETERmmDi =156501565025200
9CORROSION ALLOWANCE (SHELL)mmCA =3.03.01.5
10TANK EQUATOR LEVEL (FROM GROUND)mmHT =108251082515600
11[SHELL µÎ²²°è»ê ³ôÀÌ[ HIGH HIGH LIQUID LEVELmmHHLL =140801408020266
12[Storage ¿ë·®°è»ê ¾×³ôÀÌ[ HIGH LIQUID LEVELmmHLL =125201252020266
13LOW LIQUID LEVELmmLLL =200020002000
14LOW LOW LIQUID LEVELmmLLLL =100010001000
15DESIGN INTERNAL PRESSUREbarPi =6.06.08.335653
16DESIGN EXTERNAL PRESSUREbarPe =1.013251.013251.01325
17MIN.DESIGN METAL TEMPERATURE¡ÉMDMT =-19-19-19
18SHELL JOINT EFFICIENCYE =0.81.01.0
19TANK QUANTITY [ÅÊÅ©¼ö·® Á÷Á¢ÀÔ·Â]UnitTQTY =1.01.01.0
20COLUMN QUANTITY [¼ö·®ÀÚµ¿°è»ê]EACQTY =101014
21SHELL SEGMENT QUANTITY [¼ö·®ÀÚµ¿°è»ê]EASQTY =8810
22CORROSION ALLOWANCE (Column/Brace)mmCACB =3.0 / 3.03.0 / 3.03.0 / 3.0
23Cylinderical Vessel Longitudinal Length
ex) Mounded Bullet Vessel(Cylinderical) Length
(m)L =64.064.064.0
¡á Thickness Calculation
24Req'd Thickness under Operating Cond. (Pi+Ps)mmtdReq =27.3322.4627.57
25Req'd Thickness under Hydro-test {MAWP} (Pt)mmtwReq =15.6215.6220.62
26Req'd Thickness under Hydro-test {MAP } (Pt)mmtmReq =15.6215.6221.29
27Req'd Thickness under External Pressue (Pe)mmteReq =25.2525.2533.71
28¡¡¡¡¡¡¡Ü Top Shell Used ThicknessmmtTops =26.026.034.5
29¡¡¡¡¡¡¡Ü Equator Used ThicknessmmtMids =27.526.034.5
30¡¡¡¡¡¡¡Ü Bottom Shell Used ThicknessmmtBtms =28.526.034.5
31¡¡¡¡¡¡¡Ü Max. [Spherical] Used ThicknessmmtUsed =28.526.034.5
32If (tUsed ¡Â 64mm) then AccetableMSG =OKOKOK
33[¡Ü Cylinder[ Req'd Thickness under Oper. (Pi+Ps)mmtdCyo =51.8142.0253.7
34[¡Ü Cylinder[ Req'd Thickness under Hydrotest(Pt)mmttCyt =34.334.344.11
35¡¡¡¡¡¡¡Ü Max. [Cylinder] Used ThicknessmmtCyli =53.043.054.5
¡á PROJECT : THE SEISMIC DESIGN MARGINS FOR SPHERICAL GAS TANKS Calculation Result
1Nominal Capacity [°øĪ¿ë·®]m©øV_nom =2006.972006.978379.16
2Storage Capacity [ÀúÀå¿ë·®]m©øV_sto =1950.431950.437541.29
3Vapor Space Capacitym©øV_hil =56.5456.54837.87
4Storage Capacity Ratio%R_Sto =97.1897.1890.0
5Vapor Space Ratio%R_vapor =2.822.8210.0
6A. WEIGHT SUMMARY
7SHELL PLATETonWs =166.145157.566541.785W(1)
8UPPER COLUMN (PLATE)TonWuc =6.6536.64832.426W(2)
9LOWER COLUMN (PIPE)TonWc =13.09613.09956.831W(3)
10CROSS BRACE (PIPE)TonWb =11.39711.39721.319W(4)
11ROOF PLATFORM & STAIRWAYTonWr =11.78611.78951.148W(5)
12WATER SPRAY AND ATTACHMENTTonWsp =10.47710.47945.465W(6)
13MANHOLE & NOZZLETonWn =12.212.219.5W(7)
14INTERNAL LADDER & ATTACHMENTTonWi =9.6269.62615.386W(8)
15ANCHOR BOLT/NUTTonWa =3.183.184.452W(9)
16COLUMN FIRE PROOFINGTonWin =30.230.270.5W(10)
22Lower-Column O.DmmDcol =609.6609.61066.8
23Lower-Column ThicknessmmTcol =12.712.716.0
24Cross-Brace O.DmmDbrace =219.1219.1219.1
25Cross-Brace ThicknessmmTbrace =12.712.712.7
26¡á EMPTY WEIGHT (1 Unit)TonWe =274.76266.18858.81We = W(1)+ .. +W(10)
27B. LOADING DATA
28¡¡CONTENTS WEIGHT (at Operating)TonWc =1212.191212.194449.36Wc = Vsto * S.G
29HYDROSTATIC TEST WATER WEIGHTTonWt =2006.972006.978379.16Wt = Vnom * 1.0
30¡¡1) VERTICAL LOAD
31EMPTY WEIGHTTonWe =274.76266.18858.81We = W(1)+ .. +W(10)
32OPERATING WEIGHTTonWo =1486.951478.375308.17Wo = We + Wc
33HYDROSTATIC TEST WEIGHTTonWh =2281.732273.159237.97Wh = We + Wt
34¡¡2) HORIZONTAL LOAD
35SEISMIC FACTOR (CS=0.25 Fix)CS =0.250.250.25
36SEISMIC LOAD (Base Shear) Vs = CS x WoTonVs =371.74369.591327.04Vs = CS x Wo
37WIND LOAD (Base Shear)TonVw =


S_SEGMENT Á¤º¸
kidsidseqTNODESCRIPTIONUNITS1S2S3S4S5S6S7S8S9S10S11
600V-1110A/BAngledeg10.020.020.016.064.020.020.010.0
601V-1110A/B´©Àû Angledeg180.0170.0150.0130.0114.050.030.010.0
602V-1110A/BHeight of Weld Point(Operaing)mm14083.013964.0813034.2511286.749438.931223.26
603V-1110A/BHeight of Weld Point(HydroTest)mm15650.015531.1214601.6512854.8111007.712795.191048.35118.88
604V-1110A/BtDesignmm27.3327.327.126.7226.3324.5524.2824.28
605V-1110A/BtVacuummm25.25
606V-1110A/BtMAWP(¼ö¾Ð½ÃÇè ÇÊ¿äµÎ²²)mm15.6215.615.4515.1614.8613.5113.2213.07
607V-1110A/BtMAP(¼ö¾Ð½ÃÇè ÇÊ¿äµÎ²²)mm15.6215.615.4515.1614.8613.5113.2213.07
608V-1110A/BBLANK
609V-1110A/BtUsedmm28.528.528.527.527.526.026.026.0
6010V-1110A/BHeight Of Each Shell Segmentmm118.88929.471746.841847.18212.521746.84929.47118.88
6011V-1110A/BSurface Area of Each Segmentm35.86645.86586.19891.133405.19586.1745.855.864
6012V-1110A/B Each Shell Weightkg1312.010261.019285.019673.087472.017587.09358.01197.0
6013V-1110A/BBLANK
kidsidseqTNODESCRIPTIONUNITS1S2S3S4S5S6S7S8S9S10S11
610V-1110A/BAngledeg10.020.020.016.064.020.020.010.0
611V-1110A/B´©Àû Angledeg180.0170.0150.0130.0114.050.030.010.0
612V-1110A/BHeight of Weld Point(Operaing)mm14083.013964.0813034.2511286.749438.931223.26
613V-1110A/BHeight of Weld Point(HydroTest)mm15650.015531.1214601.6512854.8111007.712795.191048.35118.88
614V-1110A/BtDesignmm22.4622.4422.2821.9821.6620.2420.0220.02
615V-1110A/BtVacuummm25.25
616V-1110A/BtMAWP(¼ö¾Ð½ÃÇè ÇÊ¿äµÎ²²)mm15.6215.615.4515.1614.8613.5113.2213.07
617V-1110A/BtMAP(¼ö¾Ð½ÃÇè ÇÊ¿äµÎ²²)mm15.6215.615.4515.1614.8613.5113.2213.07
618V-1110A/BBLANK
619V-1110A/BtUsedmm26.026.026.026.026.026.026.026.0
6110V-1110A/BHeight Of Each Shell Segmentmm118.88929.471746.841847.18212.521746.84929.47118.88
6111V-1110A/BSurface Area of Each Segmentm35.86445.8586.1791.116405.11886.1745.855.864
6112V-1110A/B Each Shell Weightkg1197.09358.017587.018597.082685.017587.09358.01197.0
6113V-1110A/BBLANK
kidsidseqTNODESCRIPTIONUNITS1S2S3S4S5S6S7S8S9S10S11
620V-1110A/BAngledeg6.412.812.89.551.545.59.512.812.86.4
621V-1110A/B´©Àû Angledeg180.0173.6160.8148.0138.587.041.532.019.26.4
622V-1110A/BHeight of Weld Point(Operaing)mm20267.520188.97119566.56118352.6817103.9717006.49
623V-1110A/BHeight of Weld Point(HydroTest)mm25200.025121.4824499.14123285.4122036.8411940.573163.161914.59700.8678.52
624V-1110A/BtDesignmm27.5727.5627.4627.2727.0725.4724.3624.3624.3624.36
625V-1110A/BtVacuummm33.71
626V-1110A/BtMAWP(¼ö¾Ð½ÃÇè ÇÊ¿äµÎ²²)mm20.6220.6120.5120.3220.1218.5417.1616.9616.7716.68
627V-1110A/BtMAP(¼ö¾Ð½ÃÇè ÇÊ¿äµÎ²²)mm21.2921.2721.1820.9920.7919.2117.8317.6317.4417.34
628V-1110A/BBLANK
629V-1110A/BtUsedmm34.534.534.534.534.534.534.534.534.534.5
6210V-1110A/BHeight Of Each Shell Segmentmm78.52622.341213.731248.5710096.278777.411248.571213.73622.3478.52
6211V-1110A/BSurface Area of Each Segmentm36.23349.40496.35299.118801.491696.79499.11896.35249.4046.233
6212V-1110A/B Each Shell Weightkg1688.013380.026094.026844.0217064.0188709.026844.026094.013380.01688.0
6213V-1110A/BBLANK

½ÃÀ۽ð£ = [2024-12-05 09:16:07.0918]
Á¾·á½Ã°£ = [2024-12-05 09:16:07.0926]

HTML END!!!